Why does the air conditioner smell?

On a sultry day, you can't turn on AC and feel refreshed enough to feel the explosion of cold air. However, if the cold air does not have a refreshing odor, it can cause major problems.

You may ask yourself, "What is that smell?" Whether or not it smells like rotten eggs or dirty socks, the air conditioner unit may need to be repaired. Learn about the different odors that can occur and find out 12 reasons why AC stinks. In addition, you will learn when to call a pro.

Tokyo Dust Free

Evaporator coil mold / mold

AC roof type dirty filter
AC-parts full of oil
Tokyo Dust Free

The smell of dirty socks

It usually occurs when you switch from using a heater to an air conditioner. Dust begins to pass through the air filter and adhere to the evaporator coil of the air conditioner unit. This dust provides an excellent foundation for odorous molds and bacteria to grow in humid environments as the seasons change.

This accumulation can occur more quickly if the proper air filters are not installed and replaced on a regular basis and are not regularly maintained.

Tokyo Dust Free

Signs of a dirty evaporator coil:

How and why mold and mold grow on the evaporator coil?

The AC unit cools the house and also removes excess moisture in the air. If that moisture is not drained properly, your air can smell like mold. Replace the filter and have the air conditioner cleaned professionally if necessary.

Pet hair

Pet hair, dust, and other contaminants can eventually get into your tubing. As contaminants build up, you may notice that the air from the vents smells like pet hair.

Tokyo Dust Free

Visible signs of bacteria, or mold / mold buildup on the evaporator coil Ice formation in the coil Weaker air flow than normal

Workaround: Have a specialist clean the evaporator coil. This usually requires some disassembly, so it is not recommended to clean it yourself

Smelly feet

Stagnant water and clogged AC units give off a stinky foot odor. With proper cleaning, this odor will disappear.

Tokyo Dust Free

What kind of inquiry do you have regarding the error code?
Daikin error code / Daikin  Error Code 

A1

There is an error in the indoor unit. The microcomputer on the printed circuit board is not working properly.

There is an error in the indoor unit. The microcomputer on the printed circuit board is not working properly:-inspection required.

A3

It is necessary to inspect the inside of the indoor unit. It is an error of the indoor unit, it is stopped. If the float switch is activated even during heating operation, it will stop.

It is necessary to inspect the inside of the indoor unit. During the cooling operation, the float switch is activated and stopped due to the rise of the water level in the drain pan. If the float switch is activated even during heating operation, it will stop:-inspection required.

A6

It is an error of the indoor unit. The fan motor is defective.

The indoor unit fan motor needs to be checked.

A7

This is an error in the indoor unit. The blade does not move due to a malfunction of the swing motor. It is necessary to check the wind direction at the exit of the indoor unit:-Inspection is required

It is an error of the indoor unit that the horizontal blade is not moving due to a malfunction of the swing motor. Need to check the  winds direction of the indoor unit outlet:-inspection required

A8

Indoor unit error. Detected an abnormal power supply voltage of the indoor unit and stopped: ・ Inspection is required.

It is an error of the indoor unit. A malfunction of the power supply voltage of the indoor unit has been detected and it has stopped:-inspection required

A9

The coil of the indoor unit electronic expansion valve has stopped due to a failure: -Inspection required

This is an error. The coil of the indoor unit electronic expansion valve has stopped due to a malfunction:-inspection required

CC

There is an error in the indoor unit. An alarm is issued due to a failure of the humidity sensor that detects humidity, but it continues to operate.

This is an error in the indoor unit. An alarm is issued due to a malfunction of the humidity sensor that detects humidity, but it will continue to work.

  CE

It is an error warning display of indoor unit error, radiation sensor system or person detection, floor temperature sensor system. But it keeps working

  But it will continue to work. Indoor unit error, It is an error warning display of the radiation sensor system or the person detection, floor temperature sensor system.

CJ

There is an error in the indoor unit. An alarm is generated due to a malfunction of the indoor air thermistor of the remote control. In many cases, operation and temperature control can be performed even if there are errors. Reset the power and try running after 2-4 minutes. If the error still persists, check the remote control if necessary

It is an error of the indoor unit. An alarm is issued due to a malfunction of the indoor air thermistor in the remote controller. In many cases, operation and temperature control can be performed even with errors. Try to reset the power supply (breaker) ) and try running after 2 to 4 minutes. If the error still persists, check the remote control if requested.  

E0

It is an error of the outdoor unit. If any protective device of the outdoor unit works, reset the power supply and try to operate it after 3 minutes. If the error still persists, you need to check it.

If the error still persists, you need to check it

E1

It is an error of the outdoor unit. The communication status between the indoor unit and the outdoor unit is abnormal and the operation stops. Reset the power and try running after 3 minutes. If the error persists, you need to check.

It is an error of the outdoor unit. The communication status between the indoor and outdoor units is not normal and it will stop running.

Reset the power supply and try running after 3 minutes.

If the error still persists, needs to be checked.

E3

It is an error of the outdoor unit. It stopped because the high pressure rose too much during operation. Need to check: -High pressure heating / cooling obstacles / Check if the air filter around the outdoor unit is dirty.

It is an error of the outdoor unit. It has stopped because the high pressure has risen too much during operation.  Need to check:-

Hgh-pressure heating / cooling obstacles / air filter dirty around the outdoor unit.

Please contact the manufacturer directly.

Daikin toll-free number 0120-88-1081

Fill out the form below 

AF

There is an error in the indoor unit. Even though the drain pump is stopped, the alarm sounds when the water level of the drain pan rises and the float switch operates repeatedly.

It is an error of the indoor unit. Even though the drain pump is in the stop condition, the water level in the drain pan rises and an alarm is issued when the float switch repeatedly operates, the operation will continue.

AH

There is an error in the indoor unit. There is a problem with the optional equipment or the electrical component is out of order.

This is an error in the indoor unit. There is a problem with the optional equipment or electrical component failure.

(Clean the dust collector in advance​​ Falcon? If it can be reproduced after cleaning, inspection is required. In many cases, operation and temperature control can be performed even if there is an error.)

(Have you cleaned the dust collection element? If it can be reproduced even after cleaning, inspection is required. In many cases, operation and temperature control can be performed even with error)

AJ

There is an error in the indoor unit. There is a problem with the capacity setting of the printed circuit board. (Reset the power supply (breaker) and try running it after 3 minutes. If the error still persists, you need to check)

It is an error of the indoor unit. It is a malfunction of the capacity setting of the printed circuit board. (Reset the power supply (breaker) and try running after 3 minutes. If the error still persists, you need to check it)

C1

There is an error in the indoor unit. It stopped due to a communication failure between the printed circuit board and the printed circuit board for the fan. -Inspection of indoor unit is required.

It is an error of the indoor unit. It is stopped due to a communication problem between the printed circuit board and the printed circuit board for the fan:-Indoor unit inspection required.

C4

There is an error in the indoor unit. It has stopped due to a failure of the thermistor that detects the temperature of the liquid pipe of the heat exchanger. -Indoor unit inspection is required.

It is an error of the indoor unit. It is stopped due to a malfunction of the thermistor that detects the liquid pipe temperature of the heat exchanger .-- Indoor unit inspection required

C5

There is an error in the indoor unit. The contents vary depending on the model of the indoor unit. Another or simultaneous type thermistor that detects the intermediate temperature of the heat exchanger has stopped due to a malfunction:-Inspection of indoor unit required

It is an error of the indoor unit. The contents differ depending on the model of the indoor unit. Separate,  or simultaneous type, the thermistor that detects the intermediate temperature of the heat exchanger has stopped due to a malfunction:-Indoor unit inspection required

C6

There is an error in the indoor unit. It stopped due to a communication failure between the printed circuit board and the printed circuit board for the fan: -The indoor unit needs to be inspected.

This is an error in the indoor unit. It has stopped due to a communication problem between the printed circuit board and the printed circuit board for the fan:-

Indoor unit inspection required.

 

C9

There is an error in the indoor unit. It has stopped due to a failure of the thermistor that detects the suction temperature of the indoor unit: -The indoor unit needs to be inspected.

It is an error of the indoor unit. It is stopped due to a malfunction of the thermistor that detects the suction temperature of the indoor unit:-Indoor unit inspection required.

 

E4

It is an error of the outdoor unit. It stopped because the low pressure dropped too much during operation. Outdoor unit inspection is required.

It has been stopped because the low pressure dropped too much during operation. Outdoor unit inspection is required.

E5

It is an error of the outdoor unit. It stopped due to the overcurrent of the compressor. Reset the power and try running after 3 minutes. If the error persists, you need to check.

It is an error of the outdoor unit. It has been stopped due to the overcurrent of the compressor. Reset the power supply and try running after 3 minutes. If the error still persists needs to be checked.

E6

It is an error of the outdoor unit. It stopped because an overcurrent flowed through the inverter compressor.

It is an error of the outdoor unit. It is stopped due to the overcurrent passed to the inverter compressor.


Please contact the manufacturer directly.

Daikin toll-free number 0120-88-1081

Thanks for submitting!

Contact us 
〒202-0012  1-5-10 Higashi-cho, Nishitokyo-shi, Tokyo
Call Us: 042 445 4979   
info@tokyodustfree.com

 

 

  All air conditioners after a few months of regular use become infected with the following:

 

Microbial Contamination”

This contamination includes a build-up of fungi, mold and bacteria.

This will happen more quickly if the appropriate air filters are not installed or replaced on a regular schedule and routine maintenance is not carried out.